USR10 is a universal safety relay/safety timer with delayable relay outputs, 3 NO +1 NC, and a +24 VDC power supply.
USR10 is used with safety devices with contacts, 1 or 2 channels , safety devices with OSSD outputs, two-hand devices, safety mats and safety edges/bumpers.
USR10 offers 0-999 seconds timer functions with a better accuracy than 1%: OFF-delay, ON-delay, Time bypass and Time reset.
A display on its front facilitate configuration and troubleshooting by displaying error codes and error log. A custom configuration can be protected by password.
The reset function is selectable between Automatic and Manual.Learn More
Eva actuator with general code for use with Adam DYN/OSSD sensors in the Eden sensor system, IP69K, yellow, 4pcs of DA 2B spacer rings are included.Learn More
Emergency stop button in Smile enclosure, Tina adaptation unit to DYNlink included, Status LED in button, 1 x M12 5-pin male connector and 1 x M12 5-pin female connector.Learn More
Connection block for series connection of up to 4 DYNlink devices. Four M12-5 female connectors for the devices. The information signal of each device can be wired separately. The cable used for the connection to the Tina 4A should have a diameter 7 - 12 mm. If less than a devices are connected, complete with Tina 1A blind plugs.Learn More
JSTD1-C Safeball, 1NO + 1NC, 10 m cable (4 leads). Ergonomic design with several grip possibilities and low activation force (approx. 2N) and flexible mounting options. Provides highest level of safety for use in two hand control applications when using two Safeballs in conjunction with appropriate safety relay or Pluto Safety PLC. Maximum load of 30VDC, 2A resistive, IP67 protection degree, plastic body.Learn More
Adaptation of devices with 2 positively driven force-guided contacts like emergency stop buttons and key switches, to the DYNlink solution. Tina 3A is mounted directly on the device enclosure to a M20 cable entry and has a M12-5 male connector for connection to the DYNlink loop.Learn More
Three-position device. Top part with LEDs and front button. Bottom part with cable gland and PCB with 10 screw connection and anti-tamper PCB.Learn More
Adaptation of devices with 2 positively driven force-guided contacts like emergency stop buttons and key switches, to the DYNlink solution. Tina 2A is mounted directly on the device enclosure to a M20 cable entry.Learn More
M12-3S M12 Y-connector for series connection of DYNlink devices with the StatusBus function. One M12-5 pole female connector (#2) for connection of the safety device, one M12-5 male connector (#1) for connection of +24VDC, 0V, the incoming dynamic signal and the StatusBus and one M12-5 female connector (#3) for the outgoing inverted dynamic signal towards another safety device or Vital/Pluto safety PLC.Learn More
Adam safety sensor unit with OSSD signals and reset with indication. M12-5 male connector, IP69K, yellow. 4pcs of DA 1B distance plates and 4pcs of DA 2B distance rings are included.Learn More
Adam safety sensor unit with OSSD signals and information output. M12-5 male connector, IP69K, yellow. 4pcs of DA 1B distance plates and 4pcs of DA 2B distance rings are included.Learn More
Emergency stop grab wire safety switch, 4NC + 4NO, Entries from both sides of the grab wire switch, Up to 250m length, yellow die cast housing, LED status indication, Conduit entry 3xM20Learn More
Adam safety sensor unit with DYNlink signal and reset with indication. M12-5 male connector, IP69K, yellow. 4pcs of DA 1B distance plate and 4pcs of DA 2B distance rings are included.Learn More
Three-position device. Top part with LEDs and front button. Bottom part with cable gland and PCB with 16 screw connections and anti-tamper PCB.Learn More