    AF80 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available.

    More about AF80-30-00-11 24-60V50/60HZ 20-60VDC Contactor

    Technical Specification
    MRP (Indian Rupees)Not for Retail Sale
    Number of Main Contacts NO3
    Compatibility AF Contactors
    Mounted Aux Contacts0 NO, 0 NC
    Max Mechanical Switching Frequency3600 cycles per hour
    Max Electrical Switching FrequencyAC-1 600 cycles per hour, AC-2 / AC-4 150 cycles per hour, AC-3 1200 cycles per hour
    Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 30 hp, (440 ... 480 V AC) Three Phase 60 hp, (550 ... 600 V AC) Three Phase 75 hp, (120 V AC) Single Phase 7-1/2 hp, (200 ... 208 V AC) Three Phase 25 hp, (240 V AC) Single Phase 15 hp
    Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 °C 130 ampere
    Terminal TypeScrew Terminals
    Rated Operational VoltageMain Circuit 1000 volt
    Operate TimeBetween Coil De-energization and NC Contact Closing 19 ... 105 millisecond, Between Coil De-energization and NO Contact Opening 17 ... 100 millisecond, Between Coil Energization and NC Contact Opening 38 ... 95 millisecond, Between Coil Energization and N
    Rated Control Circuit Voltage (Uc)50 Hz 24-60V; 50 Hz / 60 Hz 24-60V; 60 Hz 24-60V; DC Operation 20-60V
    Rated Operational Power AC-3 (Pe)(1000 V) 250 KWT, (220 / 230 / 240 V) 22 KWT, (380 / 400 V) 37 KWT, (415 V) 45 KWT, (440 V) 45 KWT, (500 V) 45 KWT, (690 V) 45 KWT, (400 V) 37 KWT
    Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 60 °C 80 ampere, (380 / 400 V) 60 °C 80 ampere, (415 V) 60 °C 80 ampere, (440 V) 60 °C 80 ampere, (500 V) 60 °C 65 ampere, (690 V) 60 °C 49 ampere, (1000 V) 60 °C 25 ampere
    Rated Operational Current AC-1 (Ie)(690 V) 40 °C 125 ampere, (690 V) 60 °C 100 ampere, (690 V) 70 °C 85 ampere
    Rated Frequency (f)Main Circuit 50 / 60 hertz
    Rated Short-time Withstand Current (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 ampere, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 ampere, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 ampere, at 40 °C Ambient Temp, in Free Air, fro
    Package Width150 millimetre
    Package Length150 millimetre
    Package Height103 millimetre
    Invoice DescriptionAF80-30-00-11 24-60V50/60HZ 20-60VDC Contactor
    Product RangeAF Contactors
    Package Gross Weight1.34 kilogram
    Extended Product TypeAF80-30-00-11
    General Use Rating UL/CSA(600 V AC) 105 ampere
    Full Load Amps Motor Use(440 ... 480 V AC) Three Phase 60 ampere, (550 ... 600 V AC) Three Phase 75 ampere, (120 V AC) Single Phase 7-1/2 ampere, (200 ... 208 V AC) Three Phase 25 ampere, (220 ... 240 V AC) Three Phase 30 ampere, (240 V AC) Single Phase 15 ampere
    Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 degree Celsius, Close to Contactor without Thermal O/L Relay -40 ... +70 degree Celsius, Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 degree Celsius
    Rated Insulation Voltage (Ui)acc. to UL/CSA 600 volt, acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 volt
    Product ClassBlock Contactors
    Total GST Percentage18.00
    HSN Number85364900
    Country of originFrance (FR) - Imported by ABB India Limited
    All Offers
    SellerQtyPriceLanding Price
    EBASCO MARKETING
    98.4% of 100
    98.4% positive evaluations
    ₹11,000.00
    Free delivery
      Paramount Industrial Corporation
      96.6% of 100
      96.6% positive evaluations
      ₹11,686.00
      Free delivery
        Download
        Declaration of Conformity - CE Click Here
        CCC Certificate Click Here
        UL Certificate Click Here
        All Offers
        SellerQtyPriceLanding Price
        EBASCO MARKETING
        98.4% of 100
        98.4% positive evaluations
        ₹11,000.00
        Free delivery
          Paramount Industrial Corporation
          96.6% of 100
          96.6% positive evaluations
          ₹11,686.00
          Free delivery
            Write Your Own Review
            You're reviewing:AF80-30-00-11 24-60V50/60HZ 20-60VDC Contactor
            Copyright © 2025 ABB India Ltd. | Address: Disha - Plot No.5 & 6, 2nd Stage, Peenya Industrial Area IV, Peenya 560058, Bangalore, Karnataka, India.