Automation & Control

AF580-30-11 48-130V 50/60Hz / 48-130V DC Contactor

Out of stock
    Product Id
    1SFL617001R6911
    A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 48-130 V, AC/DC

    More about AF580-30-11 48-130V 50/60Hz / 48-130V DC Contactor

    Technical Specification
    MRP (Indian Rupees)Not for Retail Sale
    Number of Main Contacts NO3
    Compatibility AF Contactors
    Mounted Aux Contacts1 NO, 1 NC
    Max Mechanical Switching Frequency300 cycles per hour
    Max Electrical Switching FrequencyAC-1 300 cycles per hour, AC-2 / AC-4 60 cycles per hour, AC-3 300 cycles per hour
    Horsepower Rating UL/CSA(200 V AC) Three Phase 200 hp, (208 V AC) Three Phase 200 hp, (220 ... 240 V AC) Three Phase 250 hp, (440 ... 480 V AC) Three Phase 500 hp, (550 ... 600 V AC) Three Phase 600 hp
    Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 °C 800 ampere
    Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 12 volt - ampere, Holding at Max. Rated Control Circuit Voltage 60 Hz 12 volt - ampere, Holding at Max. Rated Control Circuit Voltage DC 5 volt - ampere, Pull-in at Max. Rated Control Circuit Voltage 50
    Terminal TypeMain Circuit: Bars
    Rated Operational VoltageMain Circuit 1000 volt
    Operate TimeBetween Coil De-energization and NC Contact Closing 50 ... 70 millisecond, Between Coil De-energization and NO Contact Opening 53 ... 73 millisecond, Between Coil Energization and NC Contact Opening 45 ... 115 millisecond, Between Coil Energization and NO
    Rated Control Circuit Voltage (Uc)50 Hz 48-130V; 60 Hz 48-130V; DC Operation 48-130V
    Rated Breaking Capacity AC-3 acc. to IEC 60947-4-18 x Ie AC-3
    Rated Operational Power AC-3 (Pe)(1000 V) 355 KWT, (220 / 230 / 240 V) 160 KWT, (380 / 400 V) 315 KWT, (415 V) 355 KWT, (440 V) 355 KWT, (500 V) 400 KWT, (690 V) 500 KWT
    Rated Operational Current DC-5 (Ie)(110 V) 1-Pole, 40 °C 800 ampere, (110 V) 2 Poles in Series, 40 °C 800 ampere, (220 V) 3 Poles in Series, 40 °C 800 ampere, (600 V) 3 Poles in Series, 40 °C 800 ampere, (850 V) 3 Poles in Series, 40 °C 800 ampere
    Rated Operational Current DC-3 (Ie)(110 V) 1-Pole, 40 °C 800 ampere, (110 V) 2 Poles in Series, 40 °C 800 ampere, (220 V) 3 Poles in Series, 40 °C 800 ampere, (600 V) 3 Poles in Series, 40 °C 800 ampere, (850 V) 3 Poles in Series, 40 °C 800 ampere
    Rated Operational Current DC-1 (Ie)(110 V) 1-Pole, 40 °C 800 ampere, (110 V) 2 Poles in Series, 40 °C 800 ampere, (220 V) 3 Poles in Series, 40 °C 800 ampere, (600 V) 3 Poles in Series, 40 °C 800 ampere, (850 V) 3 Poles in Series, 40 °C 800 ampere
    Rated Operational Current AC-3 (Ie)(1000 V) 55 °C 250 ampere, (220 / 230 / 240 V) 55 °C 580 ampere, (380 / 400 V) 55 °C 580 ampere, (415 V) 55 °C 580 ampere, (440 V) 55 °C 580 ampere, (500 V) 55 °C 580 ampere, (690 V) 55 °C 500 ampere
    Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 800 ampere, (1000 V) 55 °C 700 ampere, (1000 V) 70 °C 580 ampere, (690 V) 40 °C 800 ampere, (690 V) 55 °C 700 ampere, (690 V) 70 °C 580 ampere
    Rated Making Capacity AC-3 acc. to IEC 60947-4-110 x Ie AC-3
    Rated Frequency Limits25 ... 400 hertz
    Rated Frequency (f)Main Circuit 50/60 hertz
    Number of Aux Contacts NO 1
    Rated Short-time Withstand Current (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 ampere, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1300 ampere, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3500 ampere, at 40 °C Ambient Temp, in Free Air,
    Max Operating Voltage UL/CSAMain Circuit 600 volt
    Package Width280 millimetre
    Package Length375 millimetre
    Package Height310 millimetre
    Invoice DescriptionAF580-30-11 48-130V 50/60Hz / 48-130V DC Contactor
    Product RangeAF Contactors
    Package Gross Weight15 kilogram
    Extended Product TypeAF580-30-11-69
    Number of Aux Contacts NC 1
    General Use Rating UL/CSA(600 V AC) 750 ampere
    Full Load Amps Motor Use(440 ... 480 V AC) Three Phase 590 ampere, (550 ... 600 V AC) Three Phase 578 ampere
    Ambient Air TemperatureClose to Contactor for Storage -40 ... +70 degree Celsius, Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... +50 degree Celsius, Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 degree Celsius
    Rated Insulation Voltage (Ui)acc. to UL/CSA 600 volt, acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 volt
    Product ClassBlock Contactors
    Number Of Poles 3
    Total GST Percentage18.00
    HSN Number85364900
    Country of originSweden (SE) - Imported by ABB India Limited
    Download
    Declaration of Conformity - CE Click Here
    CCC Certificate Click Here
    Write Your Own Review
    You're reviewing:AF580-30-11 48-130V 50/60Hz / 48-130V DC Contactor
    Copyright © 2025 ABB India Ltd. | Address: Disha - Plot No.5 & 6, 2nd Stage, Peenya Industrial Area IV, Peenya 560058, Bangalore, Karnataka, India.